Can a Power Station Run a Gas Furnace in an Outage?

Often yes, and it is one of the best uses of a large power station in winter. The catch is the wiring: most furnaces are hard-wired.

By · Updated · 5 steps

This page was drafted with AI assistance from manufacturers' specs and manuals, and is checked by our editor.

Short answer: often yes, if the station can cover the blower's start-up and the furnace is connected safely. A gas furnace burns gas for heat, but it needs electricity for its blower, igniter and control board. Research from Oak Ridge National Laboratory for the U.S. Department of Energy notes that gas furnaces consume both electricity and natural gas, so a power cut leaves the house without heat even when gas still flows.

The blower usually draws far less than a plug-in space heater, which is why running the furnace is often a better use of a battery than a heater (see can a power station run a space heater).

Step 1: find what the furnace draws

Look for the data plate inside the furnace's front panel or on the blower motor. It lists the motor's current in amps. Multiply amps by 120 volts for an upper estimate of running watts: a blower rated 5 A works out to about 600 W.

Motors also draw a short surge when they start. Check that the station's peak or surge rating covers it, and leave headroom on the continuous rating.

Step 2: estimate runtime

A furnace cycles on and off with the thermostat, so its average draw is lower than its running watts. As an example only, a blower using 600 W that runs half the time averages 300 W. Using our 80% usable-energy rule from the sizing guide:

  • A 2,048 Wh station: about 1,640 Wh usable, about 5.5 hours.
  • A 4,096 Wh station such as the EcoFlow DELTA Pro 3: about 3,280 Wh usable, about 11 hours.

Your furnace's figures and the weather will change these numbers a lot. Watch the station's display on the first cold night to see your real average.

Step 3: connect it the safe way

Most furnaces are hard-wired to their own circuit, so there is no plug. The safe connection is a transfer switch or a backup panel installed by a licensed electrician. It separates the circuit from the utility lines while the station powers it.

  • EcoFlow sells DELTA Pro 3 bundles that include its Transfer Switch, which it lists as cULus 1008 listed. EcoFlow's Transfer Switch page says the setup requires a licensed electrician, and its Smart Home Panel installation manual says that product must be installed by a licensed electrician and verified by the local authority having jurisdiction.
  • Anker sells the SOLIX F3800 Plus with a 10-circuit manual transfer switch, which Anker lists as certified to UL 1008 and meeting article 702 of the NEC. Anker markets one kit as plug-and-play, but a transfer switch is still wired into your breaker panel, so check your local permit rules and use an electrician for that part.

Never connect a power station to house wiring through a wall or dryer outlet. Ask the electrician to put the furnace on one of the backed-up circuits.

Before the storm

  • Test the setup on a mild day: switch over, run the furnace through a full cycle and note the draw.
  • Test smoke and CO alarms; the CPSC recommends testing them monthly.
  • Keep the station charged and indoors, where it stays warm enough to recharge. See charging a power station in the cold.

Sources

Step by step

  1. 1

    Read the furnace data plate

    Find the blower motor's amps on the furnace or motor label.

  2. 2

    Convert to watts

    Multiply amps by 120 volts for an upper estimate of running watts, and check the station's surge rating covers the motor start.

  3. 3

    Estimate runtime

    Multiply the station's rated watt-hours by 0.8 and divide by the furnace's average watts.

  4. 4

    Hire a licensed electrician

    Have a transfer switch or backup panel installed that is approved for your power station, with the furnace on a backed-up circuit.

  5. 5

    Test before the storm

    Switch over on a mild day and run the furnace through a full heating cycle.

Frequently asked questions

Will a gas furnace work without electricity?
Most will not: the blower, igniter and controls need power. Oak Ridge National Laboratory research for the Department of Energy notes that gas furnaces consume both electricity and natural gas.
Can I plug my furnace into a power station?
Most furnaces are hard-wired with no plug. Use a transfer switch or backup panel installed by a licensed electrician; EcoFlow says the setup of its Transfer Switch requires one.
How big a power station do I need for a furnace?
Check the blower's amps on the data plate, multiply by 120 for watts, and make sure the station's surge and continuous ratings cover it. Then size capacity for the hours you need, using about 80% of the rated watt-hours as usable.